Nominal voltage | |
---|---|
Specific value | 24 VDC |
Limit values, min/max | 11/27 VDC |
Nominal current, typically | |
Specific value | 280 mA |
Condition | unloaded |
Integrated heating | |
Equipment | Option |
Nominal voltage | 24 VDC ± 5 % |
Nominal power | 48 W |
Integrated water cooling | |
Equipment | Option |
Device design | |
Type | Single-/Multi-Turn |
Redundant scanning system | yes, double |
Total resolution | <= 31 Bit |
Number of steps per revolution | <= 8192 |
Number of revolutions | <= 256000 |
Output capacity | <= 25 Bit |
Accuracy | ± 1.0 ° System 1/2 |
PROFIBUS - Interface | |
PROFIBUS-DP V0 | IEC 61158, IEC 61784 |
PNO Encoder-Profile | Class 1 and 2 |
SSI - Interface | |
Equipment | Standard interface |
SSI-Clock input | Optocoupler |
SSI-Data output | RS-422, 2-wire |
SSI-Clock frequency | 80…1000 kHz |
SSI-Mono time, typically | 18 µs |
Incremental - Interface | |
Equipment | Standard interface |
Incremental signals, square | K1± K2± |
Impulses, square wave | 1024 or 2048 |
Output driver, TTL | RS-422, 5 VDC |
Output driver, HTL | Push-Pull, 11…27 VDC |
Type of parametrization | Factory setting |
Transmission rate | |
Specific value | 9.6…12000 kbit/s |
Cycle time | 250 µs |
Parameter/Function, changeable | Resolution |
Output code | |
Limit switch | |
External Preset inputs | |
Adjustment - Parameter | |
SSI-Parameter | |
Counting direction | |
Gear function | |
Velocity parameter | |
Type of parametrization | programmable |
Programming - Tool | Fieldbus-Device |
External inputs | |
Preset | electronic adjustment |
Logic level | "0“ < +2V, "1“ = Supply |
Maximum Speed, mechanically | <= 3600 1/min |
Shaft load, axial/radial | <= 100 N, <= 150 N |
Bearing life time | >= 2.8E+10 revolutions |
Bearing life time - Parameter | |
Speed | 3000 1/min |
Operating temperature | 60 °C |
Shaft load, axial/radial | <= 60 N, <= 90 N |
Point of origin, shaft load | at the shaft end |
<img class="</p> |